Home

Manufacturer

Electronic Technologies and Metrological Systems Company

4 Savelkinsky Proyezd, 21st floor, Zelenograd (Moscow), Russia, 124482 (Sales department: Office 2104)

zetms@made-in-zelenograd.com

Accelerometers with integrated ICP electronics

The accelerometers can be connected directly to an A17 spectrum analyzer. Some accelerometers support Transducer Electronic Data Sheet (TEDS) technology, which enables the spectrum analyzer to automatically determine the type of sensor and its sensitivity in accordance with the IEEE P1451.4 standard.

AppearanceNameDescription
AP2019 AP2031Miniature accelerometers. Designed to measure vibration and shock acceleration in diagnostic systems and in laboratory studies under conditions of strong electromagnetic fields. Sensitivity: AP2019: 0.5 mV/g. AP2031: 3 mV/g.
BC110 BC112General-purpose accelerometers with integrated electronics. Sensitivity: 100 mV/g. Frequency range: BC 112: (0.5-5,000) Hz, BC 110: (0.5-12,000) Hz. TEDS technology.
BC202General-purpose accelerometer. Sensitivity 100 mV/g. Frequency range up to 2500 Hz.
BC111 AP2037 AP28 AP98General-purpose accelerometers. Sensitivity: BC 111: (10-100) mV/g, AP 2037, AP 28: (10-100) mV/g., AP 98: (30-500) mV/g.
AP2038 AP2082MThree-axis accelerometers can determine the volume phase portrait of vibration accelerations at the point of their attachment to the object. Sensitivity of the AP2038: 10 mV/g. AP2082M: 100 mV/g.
AP35 AP36Industrial accelerometers. Explosion-proof version. Sensitivity: AP35: (10-100) mV/g. AP36: (30-100) mV/g.
AP71Industrial 3-axis explosion-proof accelerometer. Sensitivity: 200-250 mV/g.
AP2050 AP99High-sensitivity accelerometers. Designed for measurements of seismic and mechanical vibrations of large structures (bridges, buildings, dams, etc.) as part of portable diagnostic systems and stationary monitoring systems. Sensitivity of the AP2050: 600 mV/g. AP99: 500 mV/g

Vibrosensor with charge output

Used to measure vibration and shock acceleration of miniature objects in portable diagnostic systems and in laboratory work. Vibrosensor with charge output gives you acceptable sensitivity in a small device featuring a one-piece anti-vibration cable

AppearanceNameDescription
AP10Reference accelerometer for checking vibrosensors by comparison with the sample. Sensitivity: 1 pC/g.
AP19 AP31 AP32Miniature accelerometers. Designed to measure vibration and shock acceleration in portable or stationary diagnostic systems or in laboratory studies. Sensitivity: AP19: 0.25 pC/g. AP31: 1.1 pC/g. AP32: 2 pC/g.
AP20Miniature 3-axis accelerometer. Sensitivity: 2 pC/g.
AP383-axis accelerometer. Sensitivity: 10 pC/g.
AP78Underwater Accelerometer. Sensitivity: 10 pC/g.
AP793-axis underwater accelerometer. Sensitivity: 2 pC/g.

Vibration sensors

Used for measuring vibration in stationary vibration diagnostics systems. A reliable device with stable characteristics, its features include electrical isolation of the piezoelectric element and built-in amplifier-converter from the housing, which prevents grounding contour currents from affecting the measurement results.

AppearanceNameDescription
AV01 AV01-01Vibration sensors with output by voltage . Explosion-proof design. Sensitivity: 4.1 mV/mm/s.
AV02 AV02-01Vibration sensors with output by current. Explosion-proof design. Sensitivity: 4-20 mA.

Calibrators

Precision instrument for adjusting and checking accelerometers (assessing errors or changing scale values). The operation of the device is based on a comparison with each other measurand and the standard:

  • Portable calibrator
  • Stationary calibrator

Send enquiry

Made in Zelenograd

free counters